51ºÚÁϳԹÏÍø

ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
51ºÚÁϳԹÏÍø

Our Group organises 3000+ Global Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ 51ºÚÁϳԹÏÍø Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

51ºÚÁϳԹÏÍø Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
Citations : 6413

Indexed In
  • CAS Source Index (CASSI)
  • Index Copernicus
  • Google Scholar
  • Sherpa Romeo
  • Academic Journals Database
  • Open J Gate
  • Genamics JournalSeek
  • JournalTOCs
  • ResearchBible
  • China National Knowledge Infrastructure (CNKI)
  • Ulrich's Periodicals Directory
  • Electronic Journals Library
  • RefSeek
  • Directory of Research Journal Indexing (DRJI)
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • Scholarsteer
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • Euro Pub
  • ICMJE
Share This Page

Chemical sensor for determination of mercury in contaminated water

4th International Conference and Exhibition on Analytical & Bioanalytical Techniques

Ahmed Khudhair Hassan

Posters: J Anal Bioanal Tech

DOI:

Abstract
In this research, we constructed chemical sensor for determining mercury in contaminated water because we needed fast, simple, low-cost, and accurate determination of mercury in different environmental systems. The constructed membrane composed of polyvinyl chloride PVC as a matrix material, 1, 5-diphenylthiocarbazone (dithizone) as electroactive compound, and di-n-butyl phthalate (DBPH) as a plasticizer. The optimum membrane composition 30% PVC, 65% DBPH, 5% dithizone exhibited the better Nernstian response. The results showed that probe is high stability along the pH range from (3.5 to 8). The electrode displays a linear log [Hg 2+ ] versus Electromotive force (EMF) response over a wide concentration range of (5×10 −6 to 1×10 −2 M) with Nernstian slope of 29.7±0.5 mV decade-1 and limit of detection 3×10 −6 M. The proposed sensor shows relatively high selectivity for mercury ion in different matrix solution, other ions had negligible interference effect on the reading. Keywords: Ion selective electrodes, Polymeric membranes, Determination of Mercury.
Biography
Ahmed Khudhair Hassan has completed his Ph.D. from Baghdad University in 2010. He is senior scientific researcher in Environment & Water Research & Technology Directorate, Ministry of Science & Technology, Iraq. He has published several papers in reputed journals.
International Conferences 2025-26
 
Meet Inspiring Speakers and Experts at our 3000+ Global

Conferences by Country

Medical & Clinical Conferences

Conferences By Subject

Top